Sign up & Download
Sign in

Comparison of lidar-derived PM<sub>10</sub> with regional modeling and ground-based observations in the frame of MEGAPOLI experiment

by P. Royer, P. Chazette, K. Sartelet, Q. J. Zhang, M. Beekmann, J.-C. Raut
Atmospheric Chemistry and Physics ()

Abstract

Abstract. An innovative approach using mobile lidar measurements was implemented to test the performances of chemistry-transport models in simulating mass concentrations (PM10) predicted by chemistry-transport models. A ground-based mobile lidar (GBML) was deployed around Paris onboard a van during the MEGAPOLI (Megacities: Emissions, urban, regional and Global Atmospheric POLlution and climate effects, and Integrated tools for assessment and mitigation) summer experiment in July 2009. The measurements performed with this Rayleigh-Mie lidar are converted into PM10 profiles using optical-to-mass relationships previously established from in situ measurements performed around Paris for urban and peri-urban aerosols. The method is described here and applied to the 10 measurements days (MD). MD of 1, 15, 16 and 26 July 2009, corresponding to different levels of pollution and atmospheric conditions, are analyzed here in more details. Lidar-derived PM10 are compared with results of simulations from POLYPHEMUS and CHIMERE chemistry-transport models (CTM) and with ground-based observations from the AIRPARIF network. GBML-derived and AIRPARIF in situ measurements have been found to be in good agreement with a mean Root Mean Square Error RMSE (and a Mean Absolute Percentage Error MAPE) of 7.2 μg m−3 (26.0%) and 8.8 μg m−3 (25.2%) with relationships assuming peri-urban and urban-type particles, respectively. The comparisons between CTMs and lidar at ~200 m height have shown that CTMs tend to underestimate wet PM10 concentrations as revealed by the mean wet PM10 observed during the 10 MD of 22.4, 20.0 and 17.5 μg m−3 for lidar with peri-urban relationship, and POLYPHEMUS and CHIMERE models, respectively. This leads to a RMSE (and a MAPE) of 6.4 μg m−3 (29.6%) and 6.4 μg m−3 (27.6%) when considering POLYPHEMUS and CHIMERE CTMs, respectively. Wet integrated PM10 computed (between the ground and 1 km above the ground level) from lidar, POLYPHEMUS and CHIMERE results have been compared and have shown similar results with a RMSE (and MAPE) of 6.3 mg m−2 (30.1%) and 5.2 mg m−2 (22.3%) with POLYPHEMUS and CHIMERE when comparing with lidar-derived PM10 with periurban relationship. The values are of the same order of magnitude than other comparisons realized in previous studies. The discrepancies observed between models and measured PM10 can be explained by difficulties to accurately model the background conditions, the positions and strengths of the plume, the vertical turbulent diffusion (as well as the limited vertical model resolutions) and chemical processes as the formation of secondary aerosols. The major advantage of using vertically resolved lidar observations in addition to surface concentrations is to overcome the problem of limited spatial representativity of surface measurements. Even for the case of a well-mixed boundary layer, vertical mixing is not complete, especially in the surface layer and near source regions. Also a bad estimation of the mixing layer height would introduce errors in simulated surface concentrations, which can be detected using lidar measurements. In addition, horizontal spatial representativity is larger for altitude integrated measurements than for surface measurements, because horizontal inhomogeneities occurring near surface sources are dampened.

Cite this document (BETA)

Readership Statistics

10 Readers on Mendeley
by Discipline
 
 
 
by Academic Status
 
50% Ph.D. Student
 
30% Post Doc
 
10% Researcher (at a non-Academic Institution)

Sign up today - FREE

Mendeley saves you time finding and organizing research. Learn more

  • All your research in one place
  • Add and import papers easily
  • Access it anywhere, anytime

Start using Mendeley in seconds!

Already have an account? Sign in