Accurate prediction of target dose-escalation and organ-at-risk dose levels for non-small cell lung cancer patients

21Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose/objective To develop a method to predict feasible organ-at-risk (OAR) and tumour dose levels of non-small cell lung cancer (NSCLC) patients prior to the start of treatment planning. Materials/methods Included were NSCLC patients treated with volumetric modulated arc therapy according to an institutional isotoxic dose-escalation protocol. A training cohort (N = 50) was used to calculate the average dose inside the OARs as a function of the distance to the planning target volume (PTV). These dose–distance relations were used in a validation cohort (N = 39) to predict dose–volume histograms (DVHs) of OARs and PTV as well as the maximum individualized PTV dose escalation. Results The validation cohort showed that predicted and achieved MLD were in agreement with each other (difference: −0.1 ± 1.9 Gy, p = 0.81). The spinal cord was dose limiting in only two patients, which was correctly predicted. The achieved mean PTV dose varied from 52 to 73 Gy and was predicted correctly with an accuracy better than 2 Gy (i.e. 1 fraction) for 79% of the patients. Conclusion We have shown that the MLD and the prescribed PTV dose could be accurately predicted for NSCLC patients. This method can guide the treatment planner to achieve optimal OAR sparing and tumour dose escalation.

Cite

CITATION STYLE

APA

Petit, S. F., & van Elmpt, W. (2015). Accurate prediction of target dose-escalation and organ-at-risk dose levels for non-small cell lung cancer patients. Radiotherapy and Oncology, 117(3), 453–458. https://doi.org/10.1016/j.radonc.2015.07.040

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free