ACTRIS non-methane hydrocarbon intercomparison experiment in Europe to support WMO-GAW and EMEP observation networks

5Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The performance of 20 European laboratories involved in long-term non-methane hydrocarbon (NMHC) measurements within the framework of Global Atmosphere Watch (GAW) and European Monitoring and Evaluation Programme (EMEP) was assessed with respect to the ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network) and GAW data quality objectives (DQOs). Compared to previous intercomparisons the DQOs of ACTRIS are much more demanding with deviations to a reference value of less than 5% and repeatability of better than 2% for mole fractions above 0.1 nmol mol-1. The participants were asked to measure both a 30 component NMHC mixture in nitrogen (NMHCN2) at approximately 1 nmol mol-1 and whole air (NMHCair), following a standardised operation procedure including zero- And calibration gas measurements. Furthermore, they had to report details on their instruments and they were asked to assess measurement uncertainties. The NMHCs were analysed either by gas chromatography-flame ionisation detection or gas chromatography-mass spectrometer methods. Most systems performed well for the NMHCN2 measurements (88%of the reported values were within the GAWDQOs and even 58% within the ACTRIS DQOs). For NMHCair generally more frequent and larger deviations to the assigned values were observed compared to NMHCN2 (77% of the reported values were within the GAW DQOs, but only 48% within the ACTRIS DQOs). Important contributors to the poorer performance in NMHC air compared to NMHCN2 were a more complex matrix and a larger span of NMHC mole fractions (0.03-2.5 nmol mol-1). Issues, which affected both NMHC mixtures, are the usage of direct vs. two-step calibration, breakthrough of C2-C3 hydrocarbons, blank values in zero-gas measurements (especially for those systems using a Nafion® Dryer), adsorptive losses of aromatic compounds, and insufficient chromatographic resolution. Essential for high-quality results are experienced operators, a comprehensive quality assurance and quality control, well characterised systems, and sufficient man-power to operate the systems and evaluate the data.

Cite

CITATION STYLE

APA

Hoerger, C. C., Werner, A., Plass-Duelmer, C., Reimann, S., Eckart, E., Steinbrecher, R., … Wenger, A. (2014, October 13). ACTRIS non-methane hydrocarbon intercomparison experiment in Europe to support WMO-GAW and EMEP observation networks. Atmospheric Measurement Techniques. Copernicus GmbH. https://doi.org/10.5194/amtd-7-10423-2014

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free