Application of high-pressure treatment to sterilization of foods

3Citations
Citations of this article
1Readers
Mendeley users who have this article in their library.

Abstract

This paper described the cases where a high-pressure treatment of 200 MPa was found to be effective against the two typical heat-resistant spores, B. subtilis and B. cereus when conducted as a pretreatment step before heat sterilization at 90 to 100°C. In addition, when the B. cereus was used as the indicator, it took 36 minutes (D=3 min.) to complete the heat sterilization at 100°C, whereas the holding time of only 6 minutes (D=0.5 min.) was enough to achieve sterility by using the Hi-Pit (high-pressure induced transformation) effect. © 2014.

Cite

CITATION STYLE

APA

Kobayashi, A., Kawamura, M., Ohara, E., Ogino, M., Hoshino, J., Yamazaki, A., & Nishiumi, T. (2014). Application of high-pressure treatment to sterilization of foods. Review of High Pressure Science and Technology/Koatsuryoku No Kagaku To Gijutsu. https://doi.org/10.4131/jshpreview.24.48