Blue cone monochromacy: Visual function and efficacy outcome measures for clinical trials

30Citations
Citations of this article
42Readers
Mendeley users who have this article in their library.

Abstract

Background: Blue Cone Monochromacy (BCM) is an X-linked retinopathy caused by mutations in the OPN1LW / OPN1MW gene cluster, encoding long (L)- and middle (M)-wavelength sensitive cone opsins. Recent evidence shows sufficient structural integrity of cone photoreceptors in BCM to warrant consideration of a gene therapy approach to the disease. In the present study, the vision in BCM is examined, specifically seeking clinically-feasible outcomes for a future clinical trial. Methods: BCM patients (n = 25, ages 5-72) were studied with kinetic and static chromatic perimetry, full-field sensitivity testing, and eye movement recordings. Vision at the fovea and parafovea was probed with chromatic microperimetry. Results: Kinetic fields with a Goldmann size V target were generally full. Short-wavelength (S-) sensitive cone function was normal or near normal in most patients. Light-adapted perimetry results on conventional background lights were abnormally reduced; 600-nm stimuli were seen by rods whereas white stimuli were seen by both rods and S-cones. Under dark-adapted conditions, 500-nm stimuli were seen by rods in both BCM and normals. Spectral sensitivity functions in the superior retina showed retained rod and S-cone functions in BCM under dark-adapted and light-adapted conditions. In the fovea, normal subjects showed L/M-cone mediation using a 650-nm stimulus under dark-adapted conditions, whereas BCM patients had reduced sensitivity driven by rod vision. Full-field red stimuli on bright blue backgrounds were seen by L/M-cones in normal subjects whereas BCM patients had abnormally reduced and rod-mediated sensitivities. Fixation location could vary from fovea to parafovea. Chromatic microperimetry demonstrated a large loss of sensitivity to red stimuli presented on a cyan adapting background at the anatomical fovea and surrounding parafovea. Conclusions: BCM rods continue to signal vision under conditions normally associated with daylight vision. Localized and retina-wide outcome measures were examined to evaluate possible improvement of L/M-cone-based vision in a clinical trial.

Cite

CITATION STYLE

APA

Luo, X., Cideciyan, A. V., Iannaccone, A., Roman, A. J., Ditta, L. C., Jennings, B. J., … Jacobson, S. G. (2015). Blue cone monochromacy: Visual function and efficacy outcome measures for clinical trials. PLoS ONE, 10(4). https://doi.org/10.1371/journal.pone.0125700

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free