Comparación de la medición del grosor corneal central medido con un nuevo equipo de tomografía con cámara de Scheimpflug y anillos de Plácido (Sirius®) y paquimetría ultrasónica en sujetos sanos

  • Garza-León M
  • de la Parra-Colín P
  • Barrientos-Gutierrez T
N/ACitations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective: To assess the repeatability and comparability of the central corneal thickness measurements obtained from a novel Scheimpflug camera with a Placido-disc topographer (Sirius®) and ultrasound pachymetry. Material and methods: In a sample of thirty unoperated eyes of healthy subjects, the central corneal thickness was analyzed by a single examiner using the Sirius® and the ultrasound pachymeter. Repeatability of three sets of measurements from each device were evaluated using the coefficient of variation, standard deviation, and intraclass correlation coefficient. T-test with Bonferroni adjustment and Bland and Altman plots were used to assess agreement between devices. Results: For the Sirius® the coefficient of variation was 0.291%, and for the ultrasound pachymeter was 0.238%. The standard deviation was 0.123μm and 0.101μm for Sirius® and US respectively and the intraclass correlation coefficient was higher than 0.95 in all measurements. Ultrasound pachymetry systematically yielded higher values and statistically significant (mean 543.867 vs 558.267μm Sirius® and ultrasound pachymeter respectively), but the difference was not clinically significant. Conclusion: In the assessment of normal corneas, central corneal thickness measured with both devices showed high repeatability and good agreement. Even though central corneal thickness measurements obtained by Sirius® were systematically lower than those obtained by ultrasound pachymeter, they do not have clinical significance. © 2014 Sociedad Mexicana de Oftalmologi

Cite

CITATION STYLE

APA

Garza-León, M., de la Parra-Colín, P., & Barrientos-Gutierrez, T. (2015). Comparación de la medición del grosor corneal central medido con un nuevo equipo de tomografía con cámara de Scheimpflug y anillos de Plácido (Sirius®) y paquimetría ultrasónica en sujetos sanos. Revista Mexicana de Oftalmología, 89(4), 225–229. https://doi.org/10.1016/j.mexoft.2014.11.011

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free