Effect of Contrast Media on Megavoltage Photon Beam Dosimetry

18Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The purpose of this study was to quantify changes in photon beam dosimetry caused by using contrast media during computed tomography (CT) simulation and determine if the resulting changes are clinically significant. The effect of contrast on dosimetry was first examined for a single 6-MV photon beam incident on a plane phantom with a structure of varying electron densities (ρe) and thickness. Patient studies were then undertaken in which CT data sets were collected with and without contrast for 6 typical patients. Three patients received IV contrast (Optiray-240™) only and 3 received IV plus oral (Gastrograffin™) contrast. Each patient was planned using conformal multifield techniques in accordance with the department standards. Two methods were used to compare the effect of contrast on dosimetry for each patient. The phantom analysis showed that the change in dose at the isocenter for a single 10 × 10 cm2 6-MV photon beam traversing 10 cm of a contrast-enhanced structure with ρe 1.22 was 7.0% (1.22 was the highest average ρe observed in the patient data). As a result of using contrast, increases in ρe were observed in structures for the 6 patients studied. Consequently, when using contrast-enhanced CT data for multifield planning, increases in dose at the isocenter and in critical structures were observed up to 2.1% and 2.5%, respectively. Planning on contrast-enhanced CT images may result in an increase in dose of up to 2.1% at the isocenter, which would generally be regarded as clinically insignificant. If, however, a critical organ is in close proximity to the planning target volume (PTV) and is planned to receive its maximum allowable dose, planning on contrast-enhanced CT images may result in that organ receiving dose beyond the recommended tolerance. In these instances, pre-contrast CT data should be used for dosimetry. © 2008 American Association of Medical Dosimetrists.

Author supplied keywords

Cite

CITATION STYLE

APA

Rankine, A. W., Lanzon, P. J., & Spry, N. A. (2008). Effect of Contrast Media on Megavoltage Photon Beam Dosimetry. Medical Dosimetry, 33(3), 169–174. https://doi.org/10.1016/j.meddos.2007.04.007

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free