Evaluation of the accuracy of the average Mu-values within patients from MR derived Mu-maps

0Citations
Citations of this article
3Readers
Mendeley users who have this article in their library.
Get full text

Abstract

We describe an evaluation of the accuracy of the estimated average μ-value within patients from MR derived μ-maps. Recently, a more optimal initial attenuation image or μ-map estimate in TOF-MLAA reconstruction has been proposed for hybrid PET/MR imaging. The proposed initial μ-map estimate is an image of the object filled with the average μ-value, and the proposed Initial Average Mu-value approach is referred to as IAM-TOF-MLAA. The average μ-value within the object is prior information which can be extracted from MR and patient database. In this work, the accuracy of the average μ-values within patients estimated from simulated MR μ-maps was evaluated using CT μ-maps as references. Clinically acquired human CT μ-maps (10 dedicated brain and 10 whole body scans) were randomly selected and used as the gold-standard. Dixon and non-Dixon MR μ-maps were simulated by replacing bone (and fat) with water as well as assigning a single μ-value for the lungs in the CT μ-maps. The average μ-value was calculated within the head, chest, and abdomen regions from the reference CT, Dixon MR, non-Dixon MR μ-maps for all patients. The error in the average μ-value obtained from the simulated MR μ-maps was evaluated, and correction factors which account for bone, fat, and uniform lungs were derived based on patient data to improve the accuracy of the estimated average μ-value. It was observed that the average μ-value within patients can be accurate within 10% from MR derived μ-map without any correction and within 5% with corrections for bone, fat and uniform lungs. It is also possible to further improve the accuracy of the average μ-value by applying the corrections derived from patients with a more specific range of body mass index and a more sufficient population size.

Cite

CITATION STYLE

APA

Cheng, J. C. K., Salomon, A., Yaqub, M., & Boellaard, R. (2016). Evaluation of the accuracy of the average Mu-values within patients from MR derived Mu-maps. In 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015. Institute of Electrical and Electronics Engineers Inc. https://doi.org/10.1109/NSSMIC.2015.7582042

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free