Expression of PD-L1 in triple-negative breast cancer based on different immunohistochemical antibodies

101Citations
Citations of this article
116Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: To date, there are no effective therapeutic targeting agents for triple-negative breast cancer (TNBC), and PD-L1 has presented potential as an effective marker of immunotherapeutic agents. The aim of this study was to evaluate the expression of PD-L1 by three different immunohistochemical antibodies in TNBC. Methods: Interpretation of all three PD-L1 antibodies showed good concordance among three readers (kappa value >0.610) in both cancer cells and immune cells. Using a tissue microarray (TMA) constructed from 218 cases of TNBC, we performed immunohistochemical staining using three of the most popular commercially used PD-L1 monoclonal antibodies (clones 28-8, E1L3N and SP142) in cancer cells and immune cells. Results: Using various cut-off values of previous studies (1, 5, 10 and 50 %), the expression rates in cancer cells were: PD-L1 (E1L3N) (14.7, 14.7, 11.0, 2.3 %), PD-L1 (28-8) (13.3, 12.4, 10.1, 1.8 %), and PD-L1 (SP142) (11.5, 11.0, 6.9, 0.5 %), respectively. At the 5 % cut-off value, the discordance rate among the three antibodies was 6.0-10.6 % and was highest between PD-L1 (SP142) and the other two antibodies. The expression rates in immune cells were PD-L1 (E1L3N) (37.6 %), PD-L1 (28-8) (36.7 %), and PD-L1 (SP142) (19.3 %), and the discordance rate among the three antibodies ranged from 13.8 to 24.8 % and was also highest between PD-L1 (SP142) and the other two antibodies. Among stromal histologic types, higher PD-L1 expression in cancer cells and immune cells was measured in inflammatory-type (p < 0.05). The absence of PD-L1 (28-8) staining in immune cells was associated with shorter disease free survival (DFS) and overall survival (OS) (p = 0.043, and p = 0.021) in univariate analyses, and with shorter OS in multivariate Cox analysis (hazard ratio: 5.429, 95 % CI 1.214-24.28, p = 0.027). Conclusions: PD-L1 detection in cancer cells and immune cells varied by antibody clone. The greatest amount of staining occurred with PD-L1 (E1L3N), followed by PD-L1 (28-8) and PD-L1 (SP142). The concordance rate among monoclonal PD-L1 antibodies was higher between PD-L1 (28-8) and PD-L1 (E1L3N). To determine the gold standard antibody and the most appropriate cut-off value, further study of the clinical trial group treated with PD-L1 inhibitor is necessary.

Cite

CITATION STYLE

APA

Sun, W. Y., Lee, Y. K., & Koo, J. S. (2016). Expression of PD-L1 in triple-negative breast cancer based on different immunohistochemical antibodies. Journal of Translational Medicine, 14(1). https://doi.org/10.1186/s12967-016-0925-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free