Flux correction for closed-path laser spectrometers without internal water vapor measurements

  • Hiller R
  • Zellweger C
  • Knohl A
  • et al.
ISSN: 1867-8610
N/ACitations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

Abstract. Recently, instruments became available on the market that provide the possibility to perform eddy covariance flux measurements of CH 4 and many other trace gases, including the traditional CO 2 and H 2 O. Most of these instruments employ laser spectroscopy, where a cross-sensitivity to H 2 O is frequently observed leading to an increased dilution effect. Additionally, sorption processes at the intake tube walls modify and delay the observed H 2 O signal in closed-path systems more strongly than the signal of the sampled trace gas. Thereby, a phase shift between the trace gas and H 2 O fluctuations is introduced that dampens the H 2 O flux observed in the sampling cell. For instruments that do not provide direct H 2 O measurement in the sampling cell, transfer functions from externally measured H 2 O fluxes are needed to estimate the effect of H 2 O on trace gas flux measurements. The effects of cross-sensitivity and the damping are shown for an eddy covariance setup with the Fast Greenhouse Gas Analyzer (FGGA, Los Gatos Research Inc.) that measures CO 2, CH 4, and H 2 O fluxes. This instrument is technically identical with the Fast Methane Analyzer (FMA, Los Gatos Research Inc.) that does not measure H 2 O concentrations. Hence, we used measurements from a FGGA to derive a modified correction for the FMA accounting for dilution as well as phase shift effects in our instrumental setup. With our specific setup for eddy covariance flux measurements, the cross-sensitivity counteracts the damping effects, which compensate each other. Hence, the new correction only deviates very slightly from the traditional Webb, Pearman, and Leuning density correction, which is calculated from separate measurements of the atmospheric water vapor flux.

Cite

CITATION STYLE

APA

Hiller, R. V., Zellweger, C., Knohl, A., & Eugster, W. (2012). Flux correction for closed-path laser spectrometers without internal water vapor measurements. Atmos.Meas.Tech.Discuss., 5(1), 351–384. Retrieved from http://www.atmos-meas-tech-discuss.net/5/351/2012/

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free