High-performance liquid chromatographic analysis of muscular interstitial arginine and norepinephrine kinetics - A microdialysis study in rats

10Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Complex interactions between the L-arginine/nitric oxide synthase (NOS) pathway and the sympathetic nervous system have been reported. Methods capable of measuring L-arginine and norepinephrine (NE) have mainly been reported for plasma. We report the use of the microdialysis technique combined with high-performance liquid chromatography (HPLC) for measurement of both L-arginine and NE within the same tissue microdialysis sample. The microdialysis probe consisted of linear flexible probes (membrane length: 10 mm, outside diameter: 290 μm, molecular weight cut-off 50 kDa). The method used for L-arginine measurement was HPLC with fluorescence detection, giving a within-run and a between-day coefficient of variation of 2.9 and 12.8%, respectively. The detection limit was 0.5 pM/20 μl injected for L-/D- arginine. The method used for NE measurement was HPLC with electrochemical detection. The coefficients of variation were 4% for within-assay precision and 7.5% for between-assay precision. The detection limit for NE was 1 fmol/20 μl injected. The microdialysis technique coupled with HPLC system was validated in vivo to measure muscular interstitial concentrations of both arginine and NE under baseline conditions and after intravenous infusion of 500 mg/kg of L-arginine or D-arginine. In conclusion, the microdialysis technique coupled to HPLC allows the simultaneous measurements of both L- arginine and NE within the same tissue microenvironment and will enable the study of the complex interactions between the L-arginine/NO pathway and sympathetic nervous system within the interstitial space of different organs. (C) 2000 Elsevier Science B.V.

Author supplied keywords

Cite

CITATION STYLE

APA

Siaghy, E. M., Devaux, Y., Schroeder, H., Sfaksi, N., Ungureanu-Longrois, D., Zannad, F., … Mertes, P. M. (2000). High-performance liquid chromatographic analysis of muscular interstitial arginine and norepinephrine kinetics - A microdialysis study in rats. Journal of Chromatography B: Biomedical Sciences and Applications, 745(2), 279–286. https://doi.org/10.1016/S0378-4347(00)00284-X

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free