Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong

54Citations
Citations of this article
60Readers
Mendeley users who have this article in their library.
Get full text

Abstract

To characterize indoor air quality at the markets in Hong Kong, three non-air-conditioned and two air-conditioned markets were selected for this study. The indoor air pollutants measured included PM10 (particulate matters with aerodynamic diameter less than 10 μm), total bacteria count (TBC), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO 2) and sulfur dioxide (SO2). The indoor and outdoor concentrations of these target air pollutants at these markets were measured and compared. The effects of air conditioning, temperature/relative humidity variation and different stalls on the indoor air quality were also investigated. The results indicated that all of the average indoor concentrations of PM 10, TBC, CO and NO2 at the markets were below the Hong Kong Indoor Air Quality Objectives (HKIAQO) standards with a few exceptions for PM10 and TBC. The elevated PM10 concentrations at Hung Hom, Ngau Tau Kok and Wan Chai markets were probably due to the air filtration of outdoor airborne particulates emitted from vehicular exhaust, whereas high concentrations of airborne bacteria at Sai Ying Pun and Tin Shing markets were linked to the use of air conditioning. Correlation analysis demonstrated that indoor bacteria concentrations were correlated with temperature and relative humidity. The operation of air conditioning did not significantly reduce the levels of air pollutants at the markets. However, the higher indoor/outdoor ratios demonstrated that the operation of air conditioning had influence on the levels of bacteria at the markets. It was found that average PM10 concentration at poultry stalls was higher than the HKIAQO standard of 180 μg/m3, and was over two times that measured at vegetable, fish and meat stalls. Furthermore, the concentration of airborne bacteria at the poultry stalls was as high as 1031 CFU/m3, which was above the HKIAQO standard of 1000 CFU/m3. The bacteria levels at other three stalls were all below the HKIAQO standard. Statistical analysis indicated that there were no significant differences among the four stalls for CO, NOx and SO2. © 2003 Elsevier B.V. All rights reserved.

Cite

CITATION STYLE

APA

Guo, H., Lee, S. C., & Chan, L. Y. (2004). Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong. Science of the Total Environment, 323(1–3), 87–98. https://doi.org/10.1016/j.scitotenv.2003.09.031

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free