Traditionally, it has been assumed that during middle-distance running oxygen uptake (V̇O2) reaches its maximal value (V̇O2max) providing the event is of a sufficient duration; however, this assumption is largely based on observations in individuals with a relatively low V̇O2max. The aim of this study was to determine whether V̇O2max is related to the V̇O2 attained (i.e. V̇O2peak) during middle-distance running on a treadmill. Fifteen well-trained male runners (age 23.3 ± 3.8 years, height 1.80 ± 0;0.10 m, body mass 76.9 ± 10.6 kg) volunteered to participate in the study. The participants undertook two 800-m trials to examine the reproducibility of the V̇O2 response. These two trials, together with a progressive test to determine V̇O2max, were completed in a randomized order. Oxygen uptake was determined throughout each test using 15-s Douglas bag collections. Following the application of a 30-s rolling average, the highest V̇O2 during the progressive test (i.e. V̇O2max) was compared with the highest V̇O2 during the 800-m trials (i.e. V̇O2peak) to examine the relationship between V̇O2max and the V̇O2 attained in the 800-m trials. For the 15 runners, V̇O2max was 58.9 ±7.1 ml · kg-1 · min-1. Two groups were formed using a median split based on V̇O2max. For the high and low V̇O2max groups, V̇O2max was 65.7 ± 3.0 and 52.4 ±1.8 ml · kg-1 · min-1 respectively. The limits of agreement (95%) for test-retest reproducibility for the V̇O2 attained during the 800-m trials were ± 3.5 ml · kg-1min ·-1 for a V̇O2peak of 50.6 ml · kg-1 · min-1 (the mean V̇O2peak for the low V̇O2max group) and ± 2.3 ml · kg-1 · min-1 for a V̇O2peak of 59.0 ml · kg-1 · min-1 (the mean V̇O2peak for the high V̇O2max group), with a bias in V̇O2peak between the 800-m runs (i.e. the mean difference) of 1.2 ml · kg-1 · min-1. The V̇O2peak for the 800-m runs was 54.8 ± 4.9 ml · kg-1 · min-1 for all 15 runners. For the high and low V̇O2max groups, V̇O2peak was 59.0 ± 3.3 ml · kg-1 · min-1 (i.e. 90% V̇O2max) and 50.6 ± 2.0 ml · kg-1 · min-1 (i.e. 97% V̇O2max) respectively. The negative relationship (-0.77) between V̇O2max and % V̇O2max attained for all 15 runners was significant (P=0.001). These results demonstrate that (i) reproducibility is good and (ii) that V̇O2max is related to the % V̇O2max achieved, with participants with a higher V̇O2max achieving a lower % V̇O2max in an 800-m trial on a treadmill.

Cite

CITATION STYLE

APA

James, D. V. B., Sandals, L. E., Draper, S. B., & Wood, D. M. (2007). Relationship between maximal oxygen uptake and oxygen uptake attained during treadmill middle-distance running. Journal of Sports Sciences, 25(8), 851–858. https://doi.org/10.1080/02640410600875226

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free