Risk of Ventricular Tachyarrhythmic Events in Patients Who Improved Beyond Guidelines for a Defibrillator in MADIT-CRT

3Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: This study assessed the arrhythmic risk of cardiac resynchronization therapy (CRT) patients who improved beyond Heart Rhythm Society/European Society of Cardiology guidelines for an implantable cardioverter-defibrillator (ICD) (ischemic cardiomyopathy: left ventricular ejection fraction [LVEF] >35% or New York Heart Association [NYHA] functional class I and if LVEF was 31% to 35%; nonischemic cardiomyopathy: LVEF >35% or NYHA functional class I and if LVEF was ≤35%). Background: It is currently unknown whether protection with a defibrillator is still warranted in patients who respond to CRT. Methods: This study compared the risk of ICD therapy for any ventricular tachyarrhythmia (VTA) and for fast VTA (≥200 beats/min) among patients implanted with a CRT with a defibrillator (CRT-D) in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy) (N = 734) who improved at 1 year beyond guideline recommendations for primary ICD therapy (group A) with those who remained within guideline recommendations for an ICD at 1 year (group B). Results: Most patients implanted with a CRT-D device improved at 1 year beyond guideline indications for an ICD (90%). Multivariate analysis showed lower risks for any VTA and fast VTA among group A patients versus group B patients (57% risk reduction; p = 0.0006 and 46% risk reduction; p = 0.068, respectively). However, the 2-year rates of any VTA and fast VTA among CRT patients who improved beyond guidelines indications for an ICD was still substantial (VTA: 13% and 29%, and fast VTA: 7% and 16%, respectively). Conclusions: Most patients with mild heart failure implanted with a CRT device experience an improvement in left ventricular function and/or NYHA functional class beyond guideline recommendations for primary ICD therapy. However, despite this pronounced CRT response, there remains a substantial VTA risk, and protection with a defibrillator may still be warranted in this population.

Cite

CITATION STYLE

APA

Sherazi, S., Shah, F., Kutyifa, V., McNitt, S., Aktas, M. K., Polonsky, B., … Goldenberg, I. (2019). Risk of Ventricular Tachyarrhythmic Events in Patients Who Improved Beyond Guidelines for a Defibrillator in MADIT-CRT. JACC: Clinical Electrophysiology, 5(10), 1172–1181. https://doi.org/10.1016/j.jacep.2019.08.009

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free