Modeling analysis of biomechanical changes of middle ear and cochlea in otitis media

13Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A comprehensive finite element (FE) model of the human ear including the ear canal, middle ear, and spiral cochlea was developed using histological sections of human temporal bone. The cochlea was modeled with three chambers separated by the basilar membrane and Reissner's membrane and filled with perilymphatic fluid. The viscoelastic material behavior was applied to middle ear soft tissues based on dynamic measurements of tissues in our lab. The model was validated using the experimental data obtained in human temporal bones and then used to simulate various stages of otitis media (OM) including the changes of morphology, mechanical properties, pressure, and fluid level in the middle ear. Function alterations of the middle ear and cochlea in OM were derived from the model and compared with the measurements from temporal bones. This study indicates that OM can be simulated in the FE model to predict the hearing loss induced by biomechanical changes of the middle ear and cochlea. © 2011 American Institute of Physics.

Cite

CITATION STYLE

APA

Gan, R. Z., Zhang, X., & Guan, X. (2011). Modeling analysis of biomechanical changes of middle ear and cochlea in otitis media. In AIP Conference Proceedings (Vol. 1403, pp. 539–544). https://doi.org/10.1063/1.3658144