Abstract
This study experimentally determines the wind loads on a stand-alone solar array (length-to-width ratio of 0.19; 1/10-scale commercial modules). The freestream velocity in a uniform flow is 14.5 ± 0.1 m/s, and the turbulence intensity is 0.3%. The angle of tilt ranges from 10° to 80° and the wind is incident at angle of 0°-180°. Mean surface pressure measurements on the upper and the lower surface of the inclined solar panels are used to calculate the lift coefficient. For the angle of incidence of 0°-60° for the wind, the variation in the lift coefficient with the angle of tilt is U-shaped. The formation of a strong windward corner vortex results in greater lift force on the right half of the inclined plate for the angle of incidence of 30°-45° for the wind.
Author supplied keywords
Cite
CITATION STYLE
Chung, P. H., Chou, C. C., Yang, R. Y., & Chung, C. Y. (2019). Wind loads on a PV array. Applied Sciences (Switzerland), 9(12). https://doi.org/10.3390/app9122466