The need of refrigerator makes an increase in use of hydrocarbon and fluorocarbon each year. Hydrocarbons and fluorocarbons are hazardous subtances that can make a damage on ozone in statosphere and increase in receive of ultraviolet on humans and give negative impact on health. Thermoelectric refrigeration as a solid state heat pump is a safe solution to subtitute the used of hidrocarbons and fluorocarbons based refrigerator. The experiment is conducted to test a thermoelectric based refrigeration system which uses water as a working fluid. The result shows that refrigeration system will be optimum at 6V and 2.24A of electricity consumption, and 0.5 litre/minute of water flowrate. While Coefficient of Performance (COP) of the system is 0.86.
CITATION STYLE
Girawan, B. A., & Ariyanto, F. (2019). Optimalisasi sistem pendingin berbasis termoelektrik berpendingin air. Dinamika Teknik Mesin, 9(1), 15. https://doi.org/10.29303/dtm.v0i0.253