Study on Related Factors of the Treatment Zone after Wearing Paragon CRT and Euclid Orthokeratology Lenses

1Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective:To explore the influence factors of the treatment zone diameter (TZD) and its relationship with axial length growth (ALG) after wearing Paragon CRT and Euclid orthokeratology lenses.Methods:The right eye data of myopic patients wearing Paragon CRT and Euclid orthokeratology in the ophthalmology department of The First Affiliated Hospital of Soochow University were retrospectively reviewed from April 2019 to October 2022. The TZD and ALG were compared between the Paragon CRT and Euclid groups. The correlation factors of TZD after wearing lens for 1 month and the relationship between the overlapping treatment zone-to-pupil area ratio and the ALG after wearing lens for 1 year were analyzed between the two groups.Results:There were 160 patients (160 eyes) in the Paragon CRT group and 155 patients (155 eyes) in the Euclid group. After wearing lens for 1 month, the TZD in the Paragon CRT group (3.72±0.37 mm) was larger than that in the Euclid group (3.26±0.37 mm) (P<0.001). The stepwise multivariate linear regression analysis showed that the eccentricity at the flattest meridians (Em) and the central corneal thickness were correlated with the TZD in both groups (P<0.05). After wearing lens for 1 year, the ALG in the Paragon CRT group (0.32±0.20 mm) was larger than that in the Euclid group (0.25±0.20 mm) (P=0.001). The stepwise multivariate linear regression analysis showed that the initial wearing age and the overlapping treatment zone area-to-pupil area ratio were correlated with the ALG in both groups (P<0.05).Conclusion:For both the Paragon CRT and Euclid orthokeratology, the wearers with thicker central corneal thickness and smaller Em usually had a smaller TZD. In both groups, the overlapping treatment zone area-to-pupil area ratio was correlated with the ALG.

Cite

CITATION STYLE

APA

Kou, S., Ren, Y., Zhuang, X., Chen, Y., & Zhang, X. (2023). Study on Related Factors of the Treatment Zone after Wearing Paragon CRT and Euclid Orthokeratology Lenses. Eye and Contact Lens, 49(12), 521–527. https://doi.org/10.1097/ICL.0000000000001035

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free