Colistin susceptibility testing of gram-negative bacilli: Better performance of vitek2 system than E-test compared to broth microdilution method as the gold standard test

8Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: Unavailability of optimal susceptibility testing (ST) challenges the clinical use of colistin. Broth microdilution (BMD), which is the reference for colistin ST, is inconvenient for diagnostics. Vitek2 and E-test although technically easier, are no longer recommended. Materials and Methods: For the evaluation of Vitek2 and E-test in reference with BMD, a total of 138 Gram-negative bacilli (GNB) especially carbapenem-resistant isolates from Tata Medical Center, Kolkata, India, were included during 2017-2018. The evaluation was performed only for Enterobacteriaceae (n = 102), but not for non-fermentative GNB (n = 36) due to lack of colistin-resistant (COLR) isolates. Results and Conclusion: Of 138 isolates, meropenem, colistin and dual resistance were detected in 110 (79.7%), 31 (22.5%) and 21 (15.2%) of isolates, respectively. Using the European Committee on Antimicrobial Susceptibility Testing guidelines (susceptible, ≤2 μg/ml), Vitek2 performed better than E-test (essential agreement, 92.2% vs. 63.7%; categorical agreement, 94.1% vs. 93.1%; very major error [VME], 10% vs. 23.3%). However, Vitek2 overcalled resistance than E-test (major error, 4.2% vs. 0%). Considering Chew et al. proposed breakpoints (susceptible, ≤1 μg/ml), VMEs declined for both test (6.7% vs. 10%), but still remained unacceptable. Of eight colistin-heteroresistant isolates, two VME were categorised by Vitek2, one VME was by E-test, and two were uninterpretable. Both Vitek2 and E-test are unreliable. Further studies correlating minimum inhibitory concentrations with clinical outcome are needed to determine the accurate breakpoints for better patient management.

Cite

CITATION STYLE

APA

Das, S., Roy, S., Roy, S., Goelv, G., Sinha, S., Mathur, P., … Bhattacharya, S. (2020). Colistin susceptibility testing of gram-negative bacilli: Better performance of vitek2 system than E-test compared to broth microdilution method as the gold standard test. Indian Journal of Medical Microbiology, 38(1), 58–65. https://doi.org/10.4103/ijmm.IJMM_19_480

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free