Serum Vitamin D Level Correlations With Tissue Vitamin D Level and Muscle Performance Before and After Rotator Cuff Repair

12Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: There is a lack of studies about serum and tissue vitamin D levels of the rotator cuff muscle on muscle power, fatty degeneration, and healing failure after rotator cuff repair (RCR). Furthermore, no studies have evaluated vitamin D receptor proteins in the rotator cuff that show a close association with serum vitamin D levels. Purpose: To evaluate the correlations between serum vitamin D and tissue vitamin D as well as perioperative variables of arthroscopic RCR. Study Design: Case series; Level of evidence, 4. Methods: From March 2017 to October 2017, a total of 36 patients who underwent RCR were prospectively enrolled, and supraspinatus muscle tissue was obtained during surgery to analyze tissue vitamin D levels. Serum vitamin D levels were checked preoperatively and at 6 months and 1 year postoperatively. Tissue vitamin D levels were assessed using liquid chromatography, and the vitamin D receptor was measured by western blotting. Isokinetic muscle performance test (IMPT; peak torque and torque deficiency compared with the opposite shoulder) results and fatty degeneration of the rotator cuff using the Goutallier classification were assessed preoperatively and at 1 year after surgery. The American Shoulder and Elbow Surgeons score and Constant score were collected at 2 years after surgery. Healing failure of the repaired rotator cuff was analyzed by magnetic resonance imaging at 1 year after surgery. Results: Overall, only three patients (8.3%) had serum vitamin D sufficiency (>20 ng/mL). Among 36 patients, 26 patients returned for their 1-year follow-up. Lower preoperative serum vitamin D levels resulted in lower serum vitamin D levels at 6 months and 1 year postoperatively (all P .05). The vitamin D receptor showed no correlation with any variables (all P >.05). Conclusion: Lower preoperative serum vitamin D levels had a strong correlation with lower tissue vitamin D levels and lower serum vitamin D levels at 1 year after surgery. Furthermore, the patients with lower serum vitamin D levels showed more weakness of muscle power perioperatively. The results of this study emphasized the association between vitamin D levels and rotator cuff muscle power.

Cite

CITATION STYLE

APA

Rhee, S. M., Park, J. H., Jeong, H. J., Kim, Y. K., Lee, K., & Oh, J. H. (2023). Serum Vitamin D Level Correlations With Tissue Vitamin D Level and Muscle Performance Before and After Rotator Cuff Repair. American Journal of Sports Medicine, 51(3), 723–732. https://doi.org/10.1177/03635465221145711

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free