Clinical outcomes of bicuspid versus tricuspid aortic valve stenosis after transcatheter aortic valve replacement with self-expandable valves

6Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: There is a lack of available data on specific prognostic comparisons between transcatheter aortic valve replacement (TAVR) using self-expandable valves (SEV) in patients with stenotic Type 0, Type 1 bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV). Objectives: To evaluate the association between aortic valve morphology and outcomes following self-expandable TAVR. Methods: Consecutive patients with aortic stenosis(AS) undergoing self-expandable TAVR were enrolled and categorized into three groups (Type 0/Type 1 BAV or TAV) according to the Sievers classification. The primary endpoint was a composite of all-cause mortality and rehospitalization for heart failure (HF) within 2 years. Secondary outcomes included procedural complications and major cardiovascular events observed in clinical follow-ups. Clinical outcomes at 2 years following TAVR were compared among three groups using Kaplan-Meier curve and multivariable Cox proportional hazards regression models. Results: A total of 344 AS patients (Type 0: 86; Type 1: 109; TAV: 149) were enrolled. The presence of moderate or severe paravalvular leak (PVL) was significantly higher in patients with Type 0 and Type 1 BAV versus TAV (10.47% vs. 16.51% vs. 6.71%, p = 0.043). All-cause 30-day mortality (2.33% vs. 0.92% vs. 2.68%, p = 0.626) and 2-year mortality (3.49% vs. 5.50% vs. 6.71%, p = 0.657) was comparable among the three groups. However, rehospitalization for HF within 2 years was significantly higher in Type 1 BAV (11.63% vs. 20.18% vs. 8.72%, p = 0.020). Multivariate Cox analysis showed that a higher STS score, Type 1 BAV morphology and excess leaflet calcification (≥ median calcium volume (CV) of the entire population) were independent predictors for HF rehospitalization. Additional intragroup Kaplan‒Meier analysis showed that excess leaflet calcification could predict higher long-term mortality and rehospitalization risk for HF(HR (95% CI): 3.430 (1.166–10.090), log rank p = 0.017) in Type 1 BAV patients. Conclusion: Outcomes of self-expandable TAVR in BAV-AS patients might vary depending on valve subtypes. BAV patients with excess leaflet calcification and a raphe, especially calcified, had an increased risk of moderate PVL and HF readmission in mid-to-long term follow-ups.

Cite

CITATION STYLE

APA

Jin, Q., Chen, S., Yang, X., Li, M., Li, W., Zhang, X., … Ge, J. (2022). Clinical outcomes of bicuspid versus tricuspid aortic valve stenosis after transcatheter aortic valve replacement with self-expandable valves. BMC Cardiovascular Disorders, 22(1). https://doi.org/10.1186/s12872-022-02943-9

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free