Reverse optic capture to stabilize a toric intraocular lens

16Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To describe a technique for stabilizing a rotationally unstable toric intraocular lens (IOL). Method: Case report and literature review. Results: Surgical technique and long-term follow-up for a patient who underwent repositioning and stabilization of a mobile 1-piece acrylic toric IOL using reverse optic capture (ROC) are described. This patient presented with early, more than 70° off-axis rotation. The IOL was repositioned but was very mobile within the bag and tended to rotate off-axis; hence, it was stabilized in the desired position by capturing the optic through the anterior continuous curvilinear capsulorhexis, leaving the haptics in the bag. The immediate and 2-year postoperative follow-up revealed a stable and on-axis IOL with no visual, refractive or ocular complications. Conclusions: ROC is a useful and safe technique to address the problem of toric IOLs that tend to rotate at the time of surgery or are not stable postoperatively. © 2013 S. Karger AG, Basel.

Cite

CITATION STYLE

APA

Gimbel, H. V., & Amritanand, A. (2013). Reverse optic capture to stabilize a toric intraocular lens. Case Reports in Ophthalmology, 4(3), 138–143. https://doi.org/10.1159/000355415