LVAD with concomitant rapid deployment valve implantation - A case report

1Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Aortic valve insufficiency can have significant hemodynamic consequences for patients with left ventricular assist devices. A circulation loop can limit systemic blood flow and increase left ventricular filling pressure. Case presentation: A 64-year-old male with non-ischemic dilated cardiomyopathy underwent Heartware™ HVAD left ventricular assist device implantation with successful concomitant aortic valve replacement with an Edwards Intuity rapid deployment prosthetic valve. Conclusions: The use of this rapid deployment valve may have benefits over other techniques including shorter cross clamp times during surgery, intermediate-long term durability, and preservation of aortic valve opening to allow for potential ventricular recovery. The Intuity rapid deployment valve should thus be considered a viable and suitable option for aortic insufficiency intervention during LVAD implantation.

Cite

CITATION STYLE

APA

Holloway, D. D., Jones, L. C., Howell, S. J., Rich, J. D., & Pham, D. T. (2019). LVAD with concomitant rapid deployment valve implantation - A case report. Journal of Cardiothoracic Surgery, 14(1). https://doi.org/10.1186/s13019-019-0944-5