Abstract

OBJECTIVES: The goal of this study was to develop and validate a method to estimate left ventricular end-systolic elastance (Ees) in humans from noninvasive single-beat parameters. BACKGROUND: Left ventricular end-systolic elastance is a major determinant of cardiac systolic function and ventricular-arterial interaction. However, its use in heart failure assessment and management is limited by lack of a simple means to measure it noninvasively. This study presents a new noninvasive method and validates it against invasively measured Ees. METHODS: Left ventricular end-systolic elastance was calculated by a modified single-beat method employing systolic (Ps) and diastolic (Pd) arm-cuff pressures, echo-Doppler stroke volume (SV), echo-derived ejection fraction and an estimated normalized ventricular elastance at arterial end-diastole (ENd): Ees(sb) = [Pd - (ENd(est) × P5 × 0.9)]/(ENd(est) × SV). The ENd was estimated from a group-averaged value adjusted for individual contractile/loading effects; Ees(sb) estimates were compared with invasively measured values in 43 patients with varying cardiovascular disorders, with additional data recorded after inotropic stimulation (n = 18, dobutamine 5 to 10 μg/kg per min). Investigators performing noninvasive analysis were blinded to the invasive results. RESULTS: Combined baseline and dobutamine-stimulated Ees ranged 0.4 to 8.4 mm Hg/ml and was well predicted by Ees(sb) over the full range: Ees = 0.86 × Ees(sb) + 0.40 (r = 0.91, SEE = 0.64, p < 0.00001, n = 72). Absolute change in Ees(sb) before and after dobutamine also correlated well with invasive measures: Ees(sb): ΔEes = 0.86 × ΔEes(sb) + 0.67 (r = 0.88, p < 0.00001). Repeated measures of Ees(sb) over two months in a separate group of patients (n = 7) yielded a coefficient of variation of 20.3 ± 6%. CONCLUSIONS: The Ees can be reliably estimated from simple noninvasive measurements. This approach should broaden the clinical applicability of this useful parameter for assessing systolic function, therapeutic response and ventricular-arterial interaction. © 2001 by the American College of Cardiology.

Cite

CITATION STYLE

APA

Chen, C. H., Fetics, B., Nevo, E., Rochitte, C. E., Chiou, K. R., Ding, P. Y. A., … Kass, D. A. (2001). Noninvasive single-beat determination of left ventricular end-systolic elastance in humans. Journal of the American College of Cardiology, 38(7), 2028–2034. https://doi.org/10.1016/S0735-1097(01)01651-5

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free