Functional outcome of extra-articular distal humerus fracture fixation using a single locking plate: A retrospective study

16Citations
Citations of this article
49Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: The optimal method for fixation of extra-articular distal humerus factures poses a management dilemma. Although various plate configurations have been proposed, anatomic shaped extra-articular distal humerus locking plates have emerged as a viable solution for these complex injuries. We assessed clinico-radiologic outcome in our retrospective case series of extra-articular distal humerus fractures managed with these plates. Methods: Forty-five patients of extra-articular distal humerus fractures, who were operated at our level 1 trauma centre between January, 2012 and December, 2016, were identified. After exclusion, 36 patients were available for the final assessment. All patients were operated with the triceps-reflecting modified posterior approach. Regular clinico-radiologic follow-up was done evaluating elbow functionality, fracture union, secondary displacement, non-union, implant failure and any complications; Mayo Elbow Performance score (MEPS) was used for the final functional assessment. Results: Twenty-four (66.7%) male and 12 (33.3%) female patients constituted the study group, who had an average follow-up of 15 months. Preoperatively three patients and post-operatively one patient had radial nerve palsy; all had neurapraxia and recovered completely. Overall, 34 (94.4%) patients were adjudged to have complete radiological union within 3 months; 2 (5.5%) patients developed nonunion. Mean flexion achieved was 122.9°±23°, and mean extension was -4.03°±6.5°; 1 patient with head injury developed flexion deformity of 45°. Average MEPS at the final follow-up was 90.8°±9.9°. Conclusion: Stable reconstruction and early initiation of physiotherapy are utilitarian to envision optimal outcome; the use of precontoured extra-articular distal humerus locking plates has yielded satisfactory results with minimal complications in our hands.

Cite

CITATION STYLE

APA

Trikha, V., Agrawal, P., Das, S., Gaba, S., & Kumar, A. (2017). Functional outcome of extra-articular distal humerus fracture fixation using a single locking plate: A retrospective study. Journal of Orthopaedic Surgery, 25(3). https://doi.org/10.1177/2309499017727948

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free