Correlation of esophageal lengths with measurable external parameters.

21Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

Previous data for esophageal lengths are based on age related groups or cadaveric examination, both of which are improper for application to various individualized procedures. Because of the variability in height for any given age and longer length in vivo, individualized approximation is needed. Thus, we measured various anatomical levels of the esophagus using a flexible endoscope and correlated these data with measurable external body intervals. The mean esophageal length was 40.92 +/- 2.79, which is longer than the length derived from cadaveric examinations. Also, esophageal lengths which correlated better with height than any other body intervals, could be calculated from the following equation. Esophageal length from the upper incisors to the esophagogastric junction (L) can be expressed: L = 0.242 x height (Ht) + 2.078 cm (P = 0.000, R2 = 0525). The data from our study indicate that esophageal length can be reliably predicted using external body parameters before employing various procedures.

Cite

CITATION STYLE

APA

Song, T. J., Kim, Y. H., Ryu, H. S., & Hyun, J. H. (1991). Correlation of esophageal lengths with measurable external parameters. The Korean Journal of Internal Medicine, 6(1), 16–20. https://doi.org/10.3904/kjim.1991.6.1.16