Linear versus Turbulent Airflow Tracheostomy Heat and Moisture Exchangers: A Crossover Study

2Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: This study aimed to evaluate the impact of two tracheostomy heat and moisture exchangers (HMEs), namely the Shikani Oxygen HME™ (S-O2HME, ball type, turbulent airflow) and Mallinckrodt Tracheolife II DAR HME (M-O2HME; flapper type, linear airflow) on tracheobronchial mucosal health, oxygenation, humidification, and patient preference. Methods: A randomized cross-over study was conducted with HME-naïve long-term tracheostomy subjects at two academic medical centers. Bronchoscopy assessments of mucosal health were performed at baseline and day 5 of HME application, along with oxygen saturation (SpO2) and breathed air humidity at four oxygen flow rates (1, 2, 3, and 5 lpm). Patient preference was assessed on study conclusion. Results: Both HMEs were associated with improved mucosal inflammation and decreased mucus production (p < 0.0002), with greater improvements in the S-O2HME group (p < 0.007). Both HMEs improved humidity concentration at each oxygen flow rate (p < 0.0001), without significant differences between groups. SpO2 was greater for the S-O2HME versus the M-O2HME across all measured oxygen flow rates (p = 0.003). At low oxygen flow rates (1 or 2 lpm), the SpO2 in the S-O2HME group was similar to that of the M-O2HME at higher oxygen flow rates (3 or 5 lpm; p = 0.6). Ninety percent of subjects preferred the S-O2HME. Conclusion: Tracheostomy HME uses correlated with improved indicators of tracheobronchial mucosal health, humidity, and oxygenation. The S-O2HME outperformed the M-O2HME with respect to tracheobronchial inflammation, SpO2, and patient preference. Regular HME use by tracheostomy patients is recommended to optimize pulmonary health. Newer ball-type speaking valve technology additionally allows concomitant HME and speaking valve application. Level of Evidence: 2 Laryngoscope, 133:3422–3428, 2023.

Cite

CITATION STYLE

APA

Shikani, A. H., Rohayem, Z., D’Adamo, C. R., & Miller, A. C. (2023). Linear versus Turbulent Airflow Tracheostomy Heat and Moisture Exchangers: A Crossover Study. Laryngoscope, 133(12), 3422–3428. https://doi.org/10.1002/lary.30795

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free