Clinical and Angiographic Outcomes with a Novel Radiopaque Sirolimus-Eluting Bioresorbable Vascular Scaffold: The FANTOM II Study

30Citations
Citations of this article
30Readers
Mendeley users who have this article in their library.

Abstract

Background: A novel bioresorbable scaffold, the sirolimus-eluting Fantom, incorporates a radiopaque polymer, struts with a thickness of 125 µm, and a crossing profile of 1.35 mm. The purpose of this study was to evaluate the 9-month angiographic and 12-month clinical outcomes of the FANTOM scaffold in a larger patient population. Methods and Results: The FANTOM II study (Safety & Performance Study of the Fantom Sirolimus-Eluting Bioresorbable Coronary Scaffold-First Report on Initial 24 Month Outcomes) was a prospective, multicenter trial which enrolled 240 patients with single de novo coronary stenosis with reference vessel diameter 2.5 to 3.5 mm diameter and lesion length ≤20 mm. Major adverse cardiac events through 12-month follow-up were assessed. Angiographic follow-up was performed in consecutive patient cohorts at 6 months (n=117) and 9 months (n=123). Acute delivery success, acute technical success, acute procedural success, and clinical procedural success rates as defined in the clinical protocol were 97.9% (235/240), 95.8% (230/240), 99.1% (228/230), and 99.6% (227/228), respectively. The mean in-stent late lumen loss at 6 months and 9 months were 0.25±0.40 mm and 0.33±0.36 mm, respectively, and in-segment binary restenosis occurred in 2.0% and 7.6% of patients, respectively. Major adverse cardiac events and target lesion failure through 12 months occurred in 4.2% of 240 patients; scaffold thrombosis developed in only one patient (0.4%). Conclusions: The Fantom sirolimus-eluting bioresorbable coronary scaffold demonstrated favorable safety and effectiveness performance at 12-month follow-up. Longer-term follow-up is ongoing to examine the late outcomes with this novel device. Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02539966.

Cite

CITATION STYLE

APA

Chevalier, B., Abizaid, A., Carrié, D., Frey, N., Lutz, M., Weber-Albers, J., … Stone, G. W. (2019). Clinical and Angiographic Outcomes with a Novel Radiopaque Sirolimus-Eluting Bioresorbable Vascular Scaffold: The FANTOM II Study. Circulation: Cardiovascular Interventions, 12(6). https://doi.org/10.1161/CIRCINTERVENTIONS.118.007283

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free