Advanced Oxidation Processes (AOPs) for Refinery Wastewater Treatment Contains High Phenol Concentration

15Citations
Citations of this article
51Readers
Mendeley users who have this article in their library.

Abstract

Petroleum Refinery wastewater is characterized by a high phenol content. Phenol is toxic and resistant to biological processes for treatment of the petroleum refinery wastewater. The combination of an AOP and a biological process can be used for treatment of the refinery wastewater. It is necessary to conduct a study to determine the appropriate condition of AOP to meet the phenol removal level. Two AOP configurations were investigated: H2O2 / UV and H2O2 / UV / O3. From each process samples, COD, phenol and pH were measured. The oxidation was carried out until the targeted phenol concentration of treated effluent were obtained. The better result obtained by using process H2O2 / UV / O3 with the H2O2 concentration 1000 ppm. After 120 minutes, the final target has been achieved in which phenol concentration of 37.5 mg/L or phenol degradation of 93.75%.

Cite

CITATION STYLE

APA

Azizah, A. N., & Widiasa, I. N. (2018). Advanced Oxidation Processes (AOPs) for Refinery Wastewater Treatment Contains High Phenol Concentration. In MATEC Web of Conferences (Vol. 156). EDP Sciences. https://doi.org/10.1051/matecconf/201815603012