Lower-sensitivity and avidity modifications of the vitros anti-HIV 1+2 assay for detection of recent HIV infections and incidence estimation

45Citations
Citations of this article
30Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Recent-infection testing assays/algorithms (RITAs) have been developed to exploit the titer and avidity of HIV antibody evolution following seroconversion for incidence estimation. The Vitros Anti-HIV 1+2 assay (Ortho-Clinical Diagnostics) was approved by the FDA to detect HIV-1 and HIV-2 infections. We developed a less-sensitive (LS) and an avidity-modified version of this assay to detect recent HIV infection. Seroconversion panels (80 subjects, 416 samples) were tested to calculate the mean duration of recent infection (MDR) for these assays. A panel from known long-term (2+ years) HIV-infected subjects on highly active antiretroviral therapy (HAART) (n = 134) and subjects with low CD4 counts (AIDS patients [n = 140]) was used to measure the false-recent rate (FRR) of the assays. Using a signal-to-cutoff ratio of 20 and the LS-Vitros assay gave a RITA MDR of 215 days (95% confidence interval [95% CI], ±65 days) and using an avidity index (AI) of 0.6 gave an MDR of 170 days (±44 days), while a combination of the two assays yielded a MDR of 146 days (±38.6) and an FRR of 8%. Misclassifying subjects with known long-term infection as recently infected occurred in 14% of AIDS patients and 29% (95% CI, 22, 38) of HAART subjects and 3% (95% CI, 0.8, 7.2) and 42% (95% CI, 33, 51), respectively, for the LS- and avidity-modified Vitros assays, with a misclassification rate of 15% (95% CI, 11, 20) overall using a dual-assay algorithm. Both modified Vitros assays can be used to estimate the length of time since seroconversion and in calculations for HIV incidence. Like other RITAs, they are subject to high FRR in subjects on HAART or with AIDS. Copyright © 2012 American Society for Microbiology. All Rights Reserved.

Cite

CITATION STYLE

APA

Keating, S. M., Hanson, D., Lebedeva, M., Laeyendecker, O., Ali-Napo, N. L., Owen, S. M., … Busch, M. P. (2012). Lower-sensitivity and avidity modifications of the vitros anti-HIV 1+2 assay for detection of recent HIV infections and incidence estimation. Journal of Clinical Microbiology, 50(12), 3968–3976. https://doi.org/10.1128/JCM.01454-12

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free