Subtalar arthroereises (STA) is a minimally invasive and reversible surgery to correct symptomatic flexible flatfoot (FFF) in children. Various techniques were described either applying expandable sinus tarsi implants or lateral calcaneus stop screws. Studies comparing the outcome of STA with different devices are rare. This retrospective single-center cohort study analyzes the results of STA using three different implants. 113 STA were performed in 73 consecutive patients (28 females). Mean age at surgery was 10.8 years (range 5–16). Mean follow-up was 29.0 months (range 1–111). In 21 feet the non-absorbable Kalix® endorthesis and in 56 feet the absorbable Giannini endorthesis were applied. Subtalar extraarticular screw arthroereises (SESA) was conducted in 36 feet. Clinical, radiographic and pedobarographic parameters were analyzed. No intraoperative complications were observed. All three procedures achieved comparable improvements of the clinical, radiographic and pedobarographic parameters. The mean foot function index (FFI) improved from 36.4 (range 12–63) to 22.8 (range 2–55). The mean preoperative calcaneal inclination angle and the lateral talocalcaneal angle improved from 9.5° (range 0–22) and 42.3° (range 21–62) to 12.8° (range 0–26) and 37.6° (range 15–56), respectively. Pedobarographically determined values of the arch index, the medial midfoot contact area and the medial forefoot peak pressure decreased. In contrast to SESA (1/36, 3%), a higher incidence of implant-related complications was observed using Kalix® (6/21, 29%) and Giannini (10/56, 8%) sinus tarsi implants. Peroneal muscle contractures only occurred in the SESA group (4/36, 11%). Premature removal due to treatment-related complications was necessary in 6/21 Kalix® implants (29%), 4/56 Giannini implants (7%) and 4/36 SESA implants (11%). Implant choice for treatment of painful FFF in children with STA seems to play a subordinate role. Clinical, radiographic and pedobarographic outcomes are comparable between the applied implants. Surgeons and patients should be aware of the different spectrum of implant-related complications. Treatment can be reliably monitored by radiation-free pedobarography providing dynamic information about the deformity.
CITATION STYLE
Vogt, B., Toporowski, G., Gosheger, G., Rölfing, J. D., Rosenbaum, D., Schiedel, F., … Frommer, A. (2021). Subtalar arthroereisis for flexible flatfoot in children—clinical, radiographic and pedobarographic outcome comparing three different methods. Children, 8(5). https://doi.org/10.3390/children8050359
Mendeley helps you to discover research relevant for your work.