High-flow oxygen via tracheostomy facilitates weaning from prolonged mechanical ventilation in patients with restrictive pulmonary dysfunction: Two case reports

15Citations
Citations of this article
32Readers
Mendeley users who have this article in their library.

Abstract

Background: Weaning from prolonged mechanical ventilation is extremely difficult in tracheostomized patients with restrictive pulmonary dysfunction. High-flow oxygen via tracheostomy supplies heated and humidified oxygen gas at > 10 L/minute. However, little has been reported on the use of high-flow oxygen via tracheostomy during weaning from ventilators in patients with restrictive pulmonary dysfunction. We report successful weaning from ventilators in patients with restrictive pulmonary dysfunction using high-flow oxygen via tracheostomy. Case presentation: The first patient is a 78-year-old Japanese man with severe pneumococcal pneumonia who was mechanically ventilated for more than 1 month after esophagectomy for esophageal cancer. After he underwent tracheostomy because of prolonged mechanical ventilation, restrictive pulmonary dysfunction appeared: tidal volume 230-240 mL and static compliance 14-15 mL/cmH2O with 10 cmH2O pressure support ventilation. He was weaned from the ventilator under inspiratory support with high-flow oxygen via tracheostomy over a period of 16 days (flow at 40 L/minute and fraction of inspired oxygen of 0.25). The second patient is a 69-year-old Japanese man who developed aspiration pneumonia after esophagectomy and received prolonged mechanical ventilation via tracheostomy. He developed restrictive pulmonary dysfunction. High-flow oxygen via tracheostomy (flow at 40 L/minute with fraction of inspired oxygen of 0.25) was administered with measurement of the airway pressure and at the entrance of the tracheostomy tube. The measured values were as follows: 0.21-0.3 cmH2O, 0.21-0.56 cmH2O, 0.54-0.91 cmH2O, 0.76-2.01 cmH2O, 1.17-2.01 cmH2O, and 1.76-2.01 cmH2O at 10 L/minute, 20 L/minute, 30 L/minute, 40 L/minute, 50 L/minute, and 60 L/minute, respectively. The airway pressures were continuously positive and did not become negative even during inspiration, suggesting that high-flow oxygen via tracheostomy reduces inspiratory effort. He was weaned from the ventilator under inspiratory support with high-flow oxygen via tracheostomy over a period of 12 days. Conclusions: High-flow oxygen via tracheostomy may reduce the inspiratory effort and enhance tidal volume by delivering high-flow oxygen and facilitate weaning from prolonged mechanical ventilation in patients with restrictive pulmonary dysfunction.

Cite

CITATION STYLE

APA

Mitaka, C., Odoh, M., Satoh, D., Hashiguchi, T., & Inada, E. (2018). High-flow oxygen via tracheostomy facilitates weaning from prolonged mechanical ventilation in patients with restrictive pulmonary dysfunction: Two case reports. Journal of Medical Case Reports, 12(1). https://doi.org/10.1186/s13256-018-1832-7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free