RANFIS-Based Sensor System with Low-Cost Multi-Sensors for Reliable Measurement of VOCs

0Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

This study describes a sensor system for continuous monitoring of volatile organic compounds (VOCs) emitted from small industrial facilities in urban centers, such as automobile paint facilities and printing facilities. Previously, intermittent measurements were made using expensive flame ionization detector (FID)-type instruments that were impossible to install, resulting in a lack of continuous management. This paper develops a low-cost sensor system for full-time management and consists of multi-sensor systems to increase the spatial resolution in the pipe. To improve the accuracy and reliability of this system, a new reinforced adaptive neuro fuzzy inference system (RANFIS) model with enhanced preprocessing based on the adaptive neuro fuzzy inference system (ANFIS) model is proposed. For this purpose, a smart sensor module consisting of low-cost metal oxide semiconductors (MOSs) and photo-ionization detectors (PIDs) is fabricated, and an operating controller is configured for real-time data acquisition, analysis, and evaluation. In the front part of the RANFIS, interquartile range (IQR) is used to remove outliers, and gradient analysis is used to detect and correct data with abnormal change rates to solve nonlinearities and outliers in sensor data. In the latter stage, the complex nonlinear relationship of the data was modeled using the ANFIS to reliably handle data uncertainty and noise. For practical verification, a toluene evaporation chamber with a sensor system for monitoring was built, and the results of real-time data sensing after training based on real data were compared and evaluated. As a result of applying the RANFIS model, the RMSE of the MQ135, MQ138, and PID-A15 sensors were 3.578, 11.594, and 4.837, respectively, which improved the performance by 87.1%, 25.9%, and 35.8% compared to the existing ANFIS. Therefore, the precision within 5% of the measurement results of the two experimentally verified sensors shows that the proposed RANFIS-based sensor system can be sufficiently applied in the field.

Cite

CITATION STYLE

APA

Kim, K., & Yang, W. (2025). RANFIS-Based Sensor System with Low-Cost Multi-Sensors for Reliable Measurement of VOCs. Technologies, 13(3). https://doi.org/10.3390/technologies13030111

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free