Effect of Print Orientation and Post-Curing Duration on the Flexural Strength, Flexural Modulus and Vickers Microhardness of a 3D-Printed Occlusal Splint Resin

3Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

Abstract

Additive manufacturing (AM) offers precision and efficiency in occlusal splint fabrication; however, the combined influence of build orientation and post-curing duration on the mechanical performance of splint resins remains insufficiently explored. This in vitro experimental study evaluated the effects of three build orientations (0°, 45°, and 90°) and three post-curing protocols (uncured, standard, and extended) on the flexural strength (FS), flexural modulus (FM) and Vickers hardness number (VHN) of a Class IIa biocompatible occlusal splint resin (NextDent Ortho Rigid). A total of 180 specimens were fabricated using a vat polymerization-type 3D printing system. Statistical analyses were conducted using one-way analyses of variance and Tukey’s tests at a significance level of α = 0.05. Both build orientation and post-curing duration significantly affected FS and VHN (p < 0.001). The combination of 45° build orientations and extended post-curing produced the highest FS (169.76 MPa) and FM (7502.17 MPa), exceeding values typically reported for 3D-printed splints, while the 90° orientation with extended curing achieved the highest VHN (21.88). Hardness gains, however, plateaued beyond standard curing, indicating a trade-off between strength and surface hardness. These results demonstrate that print orientation and post-curing time are decisive parameters in optimizing the mechanical performance of 3D-printed occlusal splints. For high-load clinical applications such as bruxism, prioritizing flexural strength over surface hardness may improve appliance longevity, supporting 45° orientation with extended curing as an evidence-based manufacturing approach.

Cite

CITATION STYLE

APA

Sahin, M., Buyuk, S. K., Simsek, H., Akdoğan, T., Bircan, S., & Toroglu, M. S. (2025). Effect of Print Orientation and Post-Curing Duration on the Flexural Strength, Flexural Modulus and Vickers Microhardness of a 3D-Printed Occlusal Splint Resin. Bioengineering, 12(12). https://doi.org/10.3390/bioengineering12121322

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free