Vitiation air heater (VAH) combustion characteristics for a direct-connect scramjet combustor (DCSC) were experimentally studied. The VAH consists of a head, modular chamber, and circular-to-rectangular shape transition (CRST) nozzle. The CRST nozzle transforms the circular cross-sectioned rocket-type VAH into a rectangular cross-sectioned scramjet combustor. The CRST nozzle exit Mach numbers at the top, middle, and bottom were measured using a tungsten wedge. The oblique shock formed by the wedge was captured using Schlieren visualization and recorded with a high-speed camera. The θ-β-M relation showed that the exit Mach number was 2.04 (Formula presented.) 0.04 with a chamber pressure of 1.685 (Formula presented.) 0.07 MPa. With the VAH design point verified, preliminary scramjet combustor ignition tests were conducted. As the fuel was not auto-ignited by the vitiated air, the forced ignition method, in which VAH ignition flame ignites the scramjet fuel, was used. The Schlieren images showed that a cavity shear layer combustion mode was formed and also showed that the forced ignition method could be used as a reference model for the ignitor-ignition method.
CITATION STYLE
Lee, J. H., Lee, E. S., Han, H. S., Kim, M. S., & Choi, J. Y. (2023). A Study on a Vitiated Air Heater for a Direct-Connect Scramjet Combustor and Preliminary Test on the Scramjet Combustor Ignition. Aerospace, 10(5). https://doi.org/10.3390/aerospace10050415