The investigation to learn about the effect resistance for Ready Mix Concrete plant waste utilized in new concrete substitute of Natural aggregate. In concrete trade natural aggregate with RMC plant waste of 7 days old waste concrete aggregate in 20% interval up to 100%. In the impact testing machine a drop weight was developed to govern impact resistance on Natural Aggregate concrete & RMC plant waste aggregate concrete. In aspect ratio (l/d) as 60 conducted Impact test on NAC & RMC waste. The samples of M40 strength of concrete. The Impact test conducted on samples as per ACI-544 committee method and verified by drop weight methods. RMC waste concrete aggregate exhibited with variation of different percentage test results of impact strength energy. The impact resistance significantly increases by additions of RMC plant waste concrete aggregate.
CITATION STYLE
Shelar, A., & Mahindrakar, D. A. (2020). Impact Resistance For Ready Mix Concrete Plant Waste Concrete Aggregate. International Journal of Recent Technology and Engineering (IJRTE), 9(1), 2311–2315. https://doi.org/10.35940/ijrte.a2743.059120
Mendeley helps you to discover research relevant for your work.