We summarized the experience from three decades of oxygen transfer testing and aeration research at the Technical University of Darmstadt to validate the oxygen transfer efficiency of modern fine-bubble diffusers. A total of 306 oxygen transfer tests in clean water of 65 different fine-bubble diffusers, carried out in the same test tank under identical test conditions, were analysed and compared with previous results. As a result, we could show that the performance of fine-bubble aeration systems has increased by 17% over the last three decades. Therefore, modern well-designed and operated aeration systems can achieve specific standard oxygen transfer efficiency (SSOTE) values between 8.5 and 9.8% · m1. Additionally, a comparison of various diffuser types and diffuser densities was done. Based on the new results, an exemplary cost/benefit analysis for a 100,000 PE WWTP shows the calculation of an optimized diffuser density with respect to investment and operating costs.
CITATION STYLE
Behnisch, J., Schwarz, M., & Wagner, M. (2020). Three decades of oxygen transfer tests in clean water in a pilot scale test tank with fine-bubble diffusers and the resulting conclusions for wwtp operation. Water Practice and Technology, 15(4), 910–920. https://doi.org/10.2166/wpt.2020.072
Mendeley helps you to discover research relevant for your work.