Evaluation of the intramammary distribution of breast lesions detected by MRI but not conventional second-look B-mode ultrasound using an MRI/ultrasound fusion technique

0Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The objective of this study was to evaluate the intramammary distribution of MRI-detected mass and focus lesions that were difficult to identify with conventional B-mode ultrasound (US) alone. Consecutive patients with lesions detected with MRI but not second-look conventional B-mode US were enrolled between May 2015 and June 2023. Following an additional supine MRI examination, we performed third-look US using real-time virtual sonography (RVS), an MRI/US image fusion technique. We divided the distribution of MRI-detected mammary gland lesions as follows: center of the mammary gland versus other (superficial fascia, deep fascia, and atrophic mammary gland). We were able to detect 27 (84%) of 32 MRI-detected lesions using third-look US with RVS. Of these 27 lesions, 5 (19%) were in the center of the mammary gland and 22 (81%) were located in other areas. We were able to biopsy all 27 lesions; 8 (30%) were malignant and 19 (70%) were benign. Histopathologically, three malignant lesions were invasive ductal carcinoma (IDC; luminal A), one was IDC (luminal B), and four were ductal carcinoma in situ (low-grade). Malignant lesions were found in all areas. During this study period, 132 MRI-detected lesions were identified and 43 (33%) were located in the center of the mammary gland and 87 (64%) were in other areas. Also, we were able to detect 105 of 137 MRI-detected lesions by second-look conventional-B mode US and 38 (36%) were located in the center of the mammary gland and 67 (64%) were in other areas. In this study, 81% of the lesions identified using third-look US with RVS and 64% lesions detected by second-look conventional-B mode US were located outside the center of the mammary gland. We consider that adequate attention should be paid to the whole mammary gland when we perform third-look US using MRI/US fusion technique.

Cite

CITATION STYLE

APA

Saito, M., Banno, H., Ito, Y., Ido, M., Goto, M., Ando, T., … Suzuki, K. (2024). Evaluation of the intramammary distribution of breast lesions detected by MRI but not conventional second-look B-mode ultrasound using an MRI/ultrasound fusion technique. BMC Medical Imaging, 24(1). https://doi.org/10.1186/s12880-024-01369-3

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free