Aiming at the problem of runner unbalance in the compounding cavity of the upper and lower cover of the correction tape box, the plastic injection analysis software Moldflow was used to optimize runner balance. First, the 3D modeling software Proe was used to establish the geometric model of the upper and lower cover of the correction tape box, and introduced into the plastic injection analysis software Moldflow. Secondly, the upper and the lower cover of the correction tape box were meshed and the initial gating system was designed in Moldflow. Filling analysis of the initial scheme of the correction tape box combined cavity showed that the runner of the melt was not balanced in the mold cavity. Finally, the runner balance optimization analysis of the cavities was carried out. Through optimization, the time unbalance rate of the melt in the mold cavity decreased from 28.6% to 0.7%, the pressure unbalance rate decreased from 42.0% to 4.2%, and the pressure distribution in the cavity was more uniform in the whole injection process.

Cite

CITATION STYLE

APA

Wang, H., & Sun, C. (2020). Optimization Analysis of Correction Tape Box Compounding Cavity Runner Balance Based on Moldflow. World Journal of Engineering and Technology, 08(01), 42–49. https://doi.org/10.4236/wjet.2020.81005