Pemasangan Sistem Pembumian pada Instalasi Listrik Balai RW 03 Beji Timur

  • Muchlishah
  • Syuhada Al Farhan
  • Dezetty Monika
  • et al.
N/ACitations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

Penelitian ini bertujuan untuk mengevaluasi efektivitas pemasangan sistem pembumian pada instalasi listrik di Balai RW 03 Beji Timur, Depok, Jawa Barat. Metode yang digunakan adalah metode deskriptif kuantitatif, dengan pengumpulan data melalui observasi langsung dan pengukuran resistansi tanah menggunakan earth tester. Data sekunder dari standar yang berlaku seperti PUIL 2011 juga digunakan untuk membandingkan hasil pengukuran di lapangan. Hasil penelitian menunjukkan bahwa variasi kedalaman penanaman elektroda berpengaruh signifikan terhadap nilai tahanan grounding. Pada kedalaman 5 meter, nilai tahanan yang diperoleh sudah sesuai dengan standar PUIL 2011, yaitu ≤ 5 Ω. Kesimpulan dari penelitian ini adalah bahwa pemasangan sistem pembumian di Balai RW 03 Beji Timur sudah memenuhi standar keamanan yang diperlukan, namun perlu adanya perbaikan pada beberapa aspek untuk meningkatkan keandalan sistem di masa mendatang.The grounding system in electrical installations is crucial for ensuring user safety and preventing equipment damage due to current surges or overvoltage. At Balai RW 03 Beji Timur, variations in soil properties lead to high soil resistance, causing the grounding system to function suboptimally and potentially fail to meet safety standards. This study aims to evaluate the effectiveness of the grounding system installation at Balai RW 03 Beji Timur, Depok, West Java. The research uses a descriptive quantitative method, collecting data through direct observation and soil resistance measurement using an earth tester. The findings show that electrode planting depth significantly affects grounding resistance. At a depth of 5 meters, the resistance remained high and did not meet the PUIL 2011 standard of ≤ 5 °C. By connecting two electrodes in parallel, the resistance value was successfully reduced to a range of 2.44–2.82 °C, meeting safety standards. Thus, a parallel-connected electrode grounding system at a depth of 5 meters provides better protection for the electrical installation at Balai RW 03 Beji Timur.

Cite

CITATION STYLE

APA

Muchlishah, Syuhada Al Farhan, Dezetty Monika, & Nuha Nadhiroh. (2024). Pemasangan Sistem Pembumian pada Instalasi Listrik Balai RW 03 Beji Timur. Electrices, 6(2), 82–88. https://doi.org/10.32722/ees.v6i2.7008

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free