Abstract
Background/Objectives: This study aimed to evaluate the clinical interchangeability of intraocular pressure (IOP) measurements between a non-contact tonometer (NCT), the TRK-3 OMNIA, and Goldmann applanation tonometry (GAT) and to assess the repeatability of TRK-3 measurements. Methods: This prospective, multicenter study included 120 subjects stratified into three IOP groups based on GAT measurements: low IOP (7–16 mmHg), intermediate IOP (>16 to <23 mmHg), and high IOP (≥23 mmHg). The study eye was randomly selected from each subject. IOP was measured using both TRK-3 OMNIA and GAT following a standardized protocol. Agreement between the two methods was evaluated using Bland–Altman analysis, 95% limits of agreement (LoA), and equivalence testing via the two one-sided test (TOST) approach with a predefined ±5 mmHg margin. Linear regression analysis was performed to characterize the relationship between TRK-3 and GAT measurements. The repeatability of TRK-3 measurements was assessed using the intraclass correlation coefficient (ICC), repeatability limit, and coefficient of variation (CV). Results: Across all subjects, the mean difference between TRK-3 OMNIA and GAT IOP measurements was −0.2 mmHg. TRK-3 OMNIA overestimated IOP in the low IOP group (mean difference: 2.1 mmHg, LoA: −1.2 to 5.4 mmHg) and underestimated in the high IOP group (mean difference: −2.4 mmHg, LoA: −5.9 to 1.1 mmHg), while agreement was highest in the intermediate IOP group (−0.2 mmHg, LoA: −2.9 to 2.5 mmHg). Despite the systematic trend, equivalence testing confirmed statistical equivalence across all groups, with 90% confidence intervals (CI) of 1.7 to 2.5 mmHg (low IOP group), −0.6 to 0.2 mmHg (intermediate IOP group), and −2.9 to −2.0 mmHg (high IOP group). Linear regression analysis found a strong correlation (r = 0.92) between TRK-3 and GAT. The TRK-3 OMNIA demonstrated good repeatability, with an ICC of 0.94, a repeatability limit of 3.12 mmHg, and a CV of 5.65%. The repeatability limits were 2.22 mmHg, 2.60 mmHg, and 4.19 mmHg in the low, intermediate, and high IOP groups, respectively. Conclusions: TRK-3 OMNIA and GAT measurements showed strong agreement, statistical equivalence, and a high correlation, supporting their clinical interchangeability. TRK-3 also demonstrated high repeatability. These findings indicate that this automated non-contact tonometer provides reliable and repeatable IOP measurements, supporting its integration into routine clinical workflows.
Author supplied keywords
Cite
CITATION STYLE
Chaglasian, M., Hou, H., Tafreshi, M., Durbin, M. K., Turhal, E., Kasanoff, D., … Huang, A. S. (2025). Clinical Assessment of Automated Non-Contact Tonometer: Interchangeability with Goldmann Applanation Tonometry and Repeatability. Journal of Clinical Medicine, 14(8). https://doi.org/10.3390/jcm14082726
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.