The paper presents a thermographic method of accelerated determination of the S-N curve. In the presented method, the S-N curve was developed based on energy-related parameter with the assumption of its dependency on the stress amplitude. The tests made on C45 steel and X5CrNi18-10 steel under reversed bending revealed that the S-N curve obtained by accelerated thermographic method fits inside the 95% confidence interval for the S-N curve obtained from the full test.
CITATION STYLE
Lipski, A. (2016). Rapid Determination of the S - N Curve for Steel by means of the Thermographic Method. Advances in Materials Science and Engineering, 2016. https://doi.org/10.1155/2016/4134021