Background It is unclear what factors affect the uptake of sevoflurane administered through the membrane oxygenator during cardiopulmonary bypass (CPB) and whether this can be monitored via the oxygenator exhaust gas. Methods Stable delivery of sevoflurane was administered to 30 elective cardiac surgery patients at 1.8 vol% (inspiratory) via the anaesthetic circuit and ventilator. During CPB, sevoflurane was administered in the oxygenator fresh gas supply (Compactflo Evolution™; Sorin Group, Milano, Italy). Sevoflurane plasma concentration (SPC) was measured using gas chromatography. Changes were correlated with bispectral index (BIS), patient temperature, haematocrit, plasma albumin concentration, oxygenator fresh gas flow, and the sevoflurane concentration in the oxygenator exhaust at predefined time points. Results The mean SPC pre-bypass was 54.9 g ml-1 [95% confidence interval (CI): 50.6-59.1]. SPC decreased to 43.2 g ml-1 (95% CI: 40.3-46.1; P<0.001) after initiation of CPB, and was lower still during rewarming and weaning from bypass, 39.4 g ml-1 (95% CI: 36.6-42.3; P<0.001). BIS did not exceed a value of 55. SPCs were higher during hypothermia (P<0.001) and with an increase in oxygenator fresh gas flow (P=0.015), and lower with haemodilution (P=0.027). No correlation was found between SPC and the concentration of sevoflurane in the oxygenator exhaust gas (r=-0.04; 95% CI: -0.18 to 0.09; P=0.53). Conclusions The uptake of sevoflurane delivered via the membrane oxygenator during CPB seems to be affected by hypothermia, haemodilution, and changes in the oxygenator fresh gas supply flow. Measuring the concentration of sevoflurane in the exhaust from the oxygenator is not useful for monitoring sevoflurane administration during bypass. © 2013 The Author. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved.
CITATION STYLE
Nitzschke, R., Wilgusch, J., Kersten, J. F., Trepte, C. J., Haas, S. A., Reuter, D. A., … Goepfert, M. S. (2013). Changes in sevoflurane plasma concentration with delivery through the oxygenator during on-pump cardiac surgery. British Journal of Anaesthesia, 110(6), 957–965. https://doi.org/10.1093/bja/aet018
Mendeley helps you to discover research relevant for your work.