Intra-fractional bladder motion and margins in adaptive radiotherapy for urinary bladder cancer

33Citations
Citations of this article
63Readers
Mendeley users who have this article in their library.

Abstract

Background. The bladder is a tumour site well suited for adaptive radiotherapy (ART) due to large inter-fractional changes, but it also displays considerable intra-fractional motion. The aim of this study was to assess target coverage with a clinically applied method for plan selection ART and to estimate population-based and patient-specific intra-fractional margins, also relevant for a future re-optimisation strategy.Material and methods. Nine patients treated in a clinical phase II ART trial of daily plan selection for bladder cancer were included. In the library plans, 5 mm isotropic margins were added to account for intra-fractional changes. Pre-treatment and weekly repeat magnetic resonance imaging (MRI) series were acquired in which a full three-dimensional (3D) volume was scanned every second min for 10 min (a total of 366 scans in 61 series). Initially, the bladder clinical target volume (CTV) was delineated in all scans. The t = 0 min scan was then rigidly registered to the planning computed tomography (CT) and plan selections were simulated using the CTV-0 (at t = 0 min). To assess intra-fractional motion, coverage of the CTV-10 (at t = 10 min) was quantified using the applied PTV. Population-based margins were calculated using the van Herk margin recipe while patient-specific margins were calculated using a linear model.Results. For 49% of the cases, the CTV-10 extended more than 5 mm outside the CTV-0. However, in 58 of the 61 cases (97%) CTV-10 was covered by the selected PTV. Population-based margins of 14 mm Sup/Ant, 9 mm Post and 5 mm Inf/Lat were sufficient to cover the bladder. Using patient-specific margins, the overlap between PTV and bowel-cavity was reduced from 137 cm3 with the plan selection strategy to 24 cm3.Conclusion. In this phase II ART trial, 5 mm isotropic margin for intra-fractional motion was sufficient even though considerable intra-fractional motion was observed. In online re-optimised ART, population-based margin can be applied although patient-specific margins are preferable.

Cite

CITATION STYLE

APA

Grønborg, C., Vestergaard, A., Høyer, M., Söhn, M., Pedersen, E. M., Petersen, J. B., … Muren, L. P. (2015). Intra-fractional bladder motion and margins in adaptive radiotherapy for urinary bladder cancer. Acta Oncologica, 54(9), 1461–1466. https://doi.org/10.3109/0284186X.2015.1062138

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free