Monitoring standard and extended half-life products in hemophilia: Assay discrepancies for factor VIII and IX in pre- and postinfusion samples

8Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Monitoring hemophilia treatment with extended half-life products is challenging for coagulation laboratories since factor assays may show substantial differences between results obtained with the one-stage assay (OSA) and the chromogenic substrate assay (CSA). Objectives: The aim of this study was to evaluate and compare different factor assays and global coagulation methods. Methods: Factor VIII (FVIII) and IX (FIX) activities and global assay parameters were analyzed in pre- and postinfusion samples (5 patients 2 samples/product/method). Results: Samples containing FVIII products (NovoEight, Elocta, and Nuwiq) gave higher levels when measured with CSA compared to OSA. The correlation was excellent (r2 ≥.97) while biases of 42%-72% of mean (CSA-OSA) were obtained. With FVIII (OSA) as independent variable, the correlations to kaolin clot time (CT) and thrombin generation assay (TGA) peak were modest (r2 =.71-.72 and.64-.65, respectively), except for Nuwiq for which there was a poor correlation to TGA peak (r2 =.08). Samples containing Alprolix, a FIX product, gave a smaller difference between activity levels (CSA-OSA), and the correlation was excellent (r2 =.96). With FIX (CSA) as independent variable for both Alprolix and Refixia, the correlations to Innovin CT and TGA peaks were weak (r2 =.33-.45 and.44-.76, respectively). Conclusions: Our data show that factor activity assays differ between methods used and agents. These discrepancies indicate the value of having more than one type of assay available in the coagulation laboratory when monitoring hemophilia treatment with extended half-life products. Global assays gave complementary information indicated by the modest correlations to factor activities.

Cite

CITATION STYLE

APA

Augustsson, C., Norström, E., Andersson, N. G., Zetterberg, E., Astermark, J., & Strandberg, K. (2020). Monitoring standard and extended half-life products in hemophilia: Assay discrepancies for factor VIII and IX in pre- and postinfusion samples. Research and Practice in Thrombosis and Haemostasis, 4(7), 1114–1120. https://doi.org/10.1002/rth2.12421

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free