Evaluation of Pain and Specimen Quality by Use of a Novel 25-Gauge Blood Collection Set With Ultra-Thin Wall Cannula and 5-Bevel Tip Design

12Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Abstract

Background: Phlebotomy has significant impact on overall patient satisfaction. Smaller gauge needles, such as a 25 gauge, may lessen patient discomfort but increase hemolysis and tube-filling times. Our studies evaluated the effect of a 5-bevel, 25-gauge blood collection set (BCS) with ultra-thin wall cannula [BD Vacutainer® UltraTouch™ Push Button BCS (UltraTouch)] on patient pain and anxiety compared with two 3-bevel, thin-wall, 23-gauge BCSs [BD Vacutainer® Safety-Lok™ (Safety-Lok) and Greiner Bio-One Vacuette® (Vacuette)]. Our studies also evaluated the 25-gauge UltraTouch for sample quality and tube filling compared with the 3-bevel, thin-wall, 23-gauge BD Vacutainer Push Button BCS. Methods: We conducted 2 studies with 214 subjects to compare pain and anxiety regarding future phlebotomy with the 3 aforementioned devices. Another study with 52 subjects assessed hemolysis in specimens collected with the UltraTouch and Push Button BCS; bench testing evaluated tube-filling times with these devices. A questionnaire captured pain upon needle insertion, overall pain, and anxiety regarding future phlebotomy. Hemolysis was evaluated visually, by Hemolysis Index and hemolysis-sensitive indicators potassium (K) and lactate dehydrogenase (LDH). Results: A statistically significant decrease was noted for overall pain with UltraTouch compared with Vacuette and with insertion pain compared with Safety-Lok. There was no significant difference in anxiety regarding future phlebotomy. No increase was observed in Hemolysis Index, K or LDH. Tube-filling times were comparable for each device. Conclusions: The 25-gauge UltraTouch provided less overall pain compared with the 23-gauge Vacuette, less pain upon needle insertion than the 23-gauge Safety-Lok, and no compromise in specimen quality or flow rate.

Cite

CITATION STYLE

APA

Mouser, A., Uettwiller-Geiger, D., Plokhoy, E., Berube, J., Ahuja, A. J., & Stankovic, A. K. (2017). Evaluation of Pain and Specimen Quality by Use of a Novel 25-Gauge Blood Collection Set With Ultra-Thin Wall Cannula and 5-Bevel Tip Design. Journal of Applied Laboratory Medicine, 2(2), 201–210. https://doi.org/10.1373/jalm.2017.023564

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free