Robot-assisted versus frame-based stereoelectroencephalography (sEEG) electrode implantation in drug-resistant epilepsy: a meta-analysis of accuracy, efficiency, and safety

1Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective: To compare the accuracy, efficiency, and safety of robot-assisted versus frame-based stereoelectroencephalography (sEEG) in patients with drug-resistant epilepsy. Methods: In accordance with the PRISMA guidelines, a comprehensive literature search was conducted across four databases (PubMed, Scopus, Web of Science, and Cochrane) up to September 2025. We included comparative studies that evaluated robot-assisted versus frame-based sEEG in patients with drug-resistant epilepsy. A random-effects model was applied to calculate the mean difference (MD) and risk ratio (RR) with corresponding 95% confidence intervals (CI). Results: Eight retrospective comparative cohort studies (758 patients) were included. Regarding accuracy, there was no significant difference between the robot-assisted and frame-based sEEG in depth error (MD: 0.24 mm; 95% CI: -0.79 to 1.27), radial error (MD: 0.07 mm; 95% CI: -0.70 to 0.84), entry point error (EPE; MD: -1.35 mm; 95% CI: -2.74 to 0.04), and target point error (MD: -0.02 mm; 95% CI: -0.57 to 0.53). Robot-assisted sEEG demonstrated a significantly shorter overall operation time (MD: -32.58 min; 95% CI: -47.92 to -17.24) and operation time per electrode (MD: -6.55 min; 95% CI: -8.08 to -5.02). However, pre-implantation time (MD: -1.46 min; 95% CI: -14.02 to 11.11) and electrode number per patient (MD: 0.86; 95% CI: -0.84 to 2.56) were comparable between groups. There was no significant difference between the two groups in overall complication rates, including hemorrhagic events, neurological deficits, infections, and technical complications. Conclusion: Robot-assisted sEEG significantly reduced both overall operation time and operation time per electrode compared with the frame-based group. Both techniques demonstrated comparable accuracy and safety profiles.

Cite

CITATION STYLE

APA

Abbas, A., Sabet, H., El Refaei, K., AbuHamdia, A., Elboraay, T., Negida, Y., … Raslan, A. M. (2026). Robot-assisted versus frame-based stereoelectroencephalography (sEEG) electrode implantation in drug-resistant epilepsy: a meta-analysis of accuracy, efficiency, and safety. Acta Neurochirurgica, 168(1). https://doi.org/10.1007/s00701-026-06787-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free