Two-hour algorithm for rapid triage of suspected acute myocardial infarction using a high-sensitivity cardiac troponin I assay

50Citations
Citations of this article
77Readers
Mendeley users who have this article in their library.
Get full text

Abstract

BACKGROUND: We aimed to derive and externally validate a 0/2-h algorithm using the high-sensitivity cardiac troponin I (hs-cTnI)-Access assay. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI) in 2 prospective diagnostic studies using central adjudication. Two independent cardiologists adjudicated the final diagnosis, including all available medical information including cardiac imaging. hs-cTnI-Access concentrations were measured at presentation and after 2 h in a blinded fashion. RESULTS: AMI was the adjudicated final diagnosis in 164 of 1131 (14.5%) patients in the derivation cohort. Rule-out by the hs-cTnI-Access 0/2-h algorithm was defined as 0-h hs-cTnI-Access concentration <4 ng/L in patients with an onset of chest pain >3 h (direct rule-out) or a 0-h hs-cTnI-Access concentration <5 ng/L and an absolute change within 2 h <5 ng/L in all other patients. Derived thresholds for rule-in were a 0-h hs-cTnI-Access concentration ≥50 ng/L (direct rule-in) or an absolute change within 2 h ≥20 ng/L. In the derivation cohort, these cutoffs ruled out 55% of patients with a negative predictive value (NPV) of 99.8% (95% CI, 99.3-100) and sensitivity of 99.4% (95% CI, 96.5-99.9), and ruled in 30% of patients with a positive predictive value (PPV) of 73% (95% CI, 66.1-79). In the validation cohort, AMI was the adjudicated final diagnosis in 88 of 1280 (6.9%) patients. These cutoffs ruled out 77.9% of patients with an NPV of 99.8% (95% CI, 99.3-100) and sensitivity of 97.7% (95% CI, 92.0 -99.7), and ruled in 5.8% of patients with a PPV of 77% (95% CI, 65.8 - 86) in the validation cohort. CONCLUSIONS: Safety and efficacy of the l hs-cTnI-Access 0/2-h algorithm for triage toward rule-out or rule-in of AMI are very high.

Cite

CITATION STYLE

APA

Nestelberger, T., Boeddinghaus, J., Greenslade, J., Parsonage, W. A., Than, M., Wussler, D., … Muzyk, P. (2019). Two-hour algorithm for rapid triage of suspected acute myocardial infarction using a high-sensitivity cardiac troponin I assay. Clinical Chemistry, 65(11), 1437–1447. https://doi.org/10.1373/clinchem.2019.305193

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free