Whole tumor section quantitative image analysis maximizes between-pathologists' reproducibility for clinical immunohistochemistry-based biomarkers

22Citations
Citations of this article
52Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Pathologists have had increasing responsibility for quantitating immunohistochemistry (IHC) biomarkers with the expectation of high between-reader reproducibility due to clinical decision-making especially for patient therapy. Digital imaging-based quantitation of IHC clinical slides offers a potential aid for improvement; however, its clinical adoption is limited potentially due to a conventional field-of-view annotation approach. In this study, we implemented a novel solely morphology-based whole tumor section annotation strategy to maximize image analysis quantitation results between readers. We first compare the field-of-view image analysis annotation approach to digital and manual-based modalities across multiple clinical studies (∼120 cases per study) and biomarkers (ER, PR, HER2, Ki-67, and p53 IHC) and then compare a subset of the same cases (∼40 cases each from the ER, PR, HER2, and Ki-67 studies) using whole tumor section annotation approach to understand incremental value of all modalities. Between-reader results for each biomarker in relation to conventional scoring modalities showed similar concordance as manual read: ER field-of-view image analysis: 95.3% (95% CI 92.0-98.2%) vs digital read: 92.0% (87.8-95.8%) vs manual read: 94.9% (91.4-97.8%); PR field-of-view image analysis: 94.1% (90.3-97.2%) vs digital read: 94.0% (90.2-97.1%) vs manual read: 94.4% (90.9-97.2%); Ki-67 field-of-view image analysis: 86.8% (82.1-91.4%) vs digital read: 76.6% (70.9-82.2%) vs manual read: 85.6% (80.4-90.4%); p53 field-of-view image analysis: 81.7% (76.4-86.8%) vs digital read: 80.6% (75.0-86.0%) vs manual read: 78.8% (72.2-83.3%); and HER2 field-of-view image analysis: 93.8% (90.0-97.2%) vs digital read: 91.0 (86.6-94.9%) vs manual read: 87.2% (82.1-91.9%). Subset implementation and analysis on the same cases using whole tumor section image analysis approach showed significant improvement between pathologists over field-of-view image analysis and manual read (HER2 100% (97-100%), P=0.013 field-of-view image analysis and 0.013 manual read; Ki-67 100% (96.9-100%), P=0.040 and 0.012; ER 98.3% (94.1-99.5%), p=0.232 and 0.181; and PR 96.6% (91.5-98.7%), p=0.012 and 0.257). Overall, whole tumor section image analysis significantly improves between-pathologist's reproducibility and is the optimal approach for clinical-based image analysis algorithms.

Cite

CITATION STYLE

APA

Barnes, M., Srinivas, C., Bai, I., Frederick, J., Liu, W., Sarkar, A., … Ranger-Moore, J. (2017). Whole tumor section quantitative image analysis maximizes between-pathologists’ reproducibility for clinical immunohistochemistry-based biomarkers. Laboratory Investigation, 97(12), 1508–1515. https://doi.org/10.1038/labinvest.2017.82

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free