Abstract

In this paper, a novel micro-positioning device based on a 3D digital actuator is presented. The proposed system allows realizing planar motions of micro-objects, which could be implemented in several applications where micro-positioning tasks are needed such as micro-component manufac-turing/assembly, biomedicine, scanning microscopy, etc. The device has three degrees of freedom, and it is able to achieve planar motions of a mobile plate in the xy-plane at two different levels along the z-axis. It consists of a hexagonal mobile part composed of a permanent magnet that can reach twelve discrete positions distributed between two z-axis levels (six at each level). Two different approaches are presented to perform positioning tasks of the plate using the digital actuator: the stick-slip and the lift-mode approaches. A comparison between these two approaches is provided on the basis of the plate displacement with respect to different current values and conveyed mass. It was observed that for a current of 2 A, the actuator is able to displace a mass of 1.15 g over a distance of 0.08 mm. The optimal positioning range of the planar device was found to be ±5.40 mm and ±7.05 mm along the x-and y-axis, respectively.

Cite

CITATION STYLE

APA

Deshmukh, A., Petit, L., Khan, M. U., Lamarque, F., & Prelle, C. (2021). Planar Micro-Positioning Device Based on a 3D Digital Electromagnetic Actuator. Actuators, 10(12). https://doi.org/10.3390/act10120310

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free